Data Cable – Cat 5, Cat 6, Cat 7
New – Cat6 Outdoor Rated & Shielded Cable from Times Microwave
Times Microwave has just released its new CAT6 SFTP LAN Data Cable, 4 pairs 23AWG
Featuring, high coverage tinned copper outer shield for superior grounding, better than 90dB RF Shielding effectiveness, ripcord for easy jacket stripping, 8mm O/D, black PE Jacket for excellent weather resistance.
CAT7 E10 MHz 4-Pair solid S/FTP, Low Smoke, Zero Halogen Cable Violet Jacket
This is a fully shield cable with individual foils around each pair, coupled with high screen
coverage outer braid for a high level of immunity to outside interference’s.
In PoE remote power applications, this cable can be installed in environments up to 60
degrees Celsius without degradation suffered by heat rise inside the cable bundle. This 7A cable
can also be used for cable sharing from one drop ideal for running multiple lower speed
applications.
Data Cable – Cat 5, Cat 6, Cat 7
The fundamental importance of the Data Centres and the need to provide for daily increasing applications, transmission speeds and data storage, businesses are investing in the amount of equipment their Data Centres must support. Consequently, IT managers must design scalable Data Centres to support their future growth and potentially new technologies, while ensuring the best performance.
Rojone supplies high quality Data cables consist of Cat.5e to Cat.7A multi-cable, multi-pair and multi-core structures solid and matched work area cables.
All cables are fully compatible with the standard connecting hardware (i.e. RJ-45).
All products are available with FR-LSZH, PVC, PU and PE jackets combined with different optional shielding structures such as S/FTP, SF/UTP, F/UTP, U/FTP.
The cables are designed with optimised lay lengths, size, transmission performance and structures to enable peak high density data-centre cabling.
High-density cabling creates less congestion in pathways which means better cooling conditions in particular for PoE and PoE+ applications, lower installation time, minimises down time, accelerates recovery time, minimises site access by non-essential personnel, and allows place-and plug modular installation for Gigabit and up to 10 Gigabit applications.
Category 5e, 100 Ohm
100 MHz Data Transmission Cables
The basic solution is a complete line of high-performance 100 Ohm cables, conforming to Category 5e in accordance with TIA/EIA-568-C, ISO/IEC 11801, IEC 61156-5, IEC 61156-6 and CENELEC prEN 50288, supporting CLASS D (new) Links.
The product range includes Horizontal, Working area (Patch) and Backbone Cables, available in a wide range of constructions, including U/UTP, F/UTP, SF/UTP and S/FTP.
All cables are available with PVC, PU (Polyurethane), PE (Polyethylene) and FR-LSZH (Flame Retardant Low Smoke Zero Halogen) jackets, in single or “Siamese twin” (FIG-8), multi-cable, or multi-core constructions.
Category 5e Data Transmission Cables
Part Number | Product Description | Computer & LAN Applications | Outer Jacket Material | Outer Diameter (mm nom.) |
---|---|---|---|---|
4T00080101 | Cat. 5e 4x2x24/1 AWG U/F/UTP + 17 AWG CCS Fig-8 Double Jacket Outdoor UL1581-VW1/CMX Jacket Outdoor UL1581-VW1/CMX | Outdoor installations | UV resistant FR-PVC | 7.9 |
8393204xxx | Cat. 5e 4x2x24/1 AWG F/UTP Outdoor PVC/PVC UL (1581 VW 1) (UL) LISTED E211498 | Outdoor installations | UV resistant FR-PVC | 7.9 |
7272604xxx | Cat. 5e 4x2x26/7 AWG Work Area U/UTP PVC | Indoor use, fixed or portable installations | FR-PVC | 4.9 |
8272626xxx | Cat. 5e 4x2x26/7 AWG F/UTP Work Area PVC | Work area cabling | FR-PVC | 5.70 |
9292604xxx | Cat. 5 4x2x26/7 AWG SF/UTP Work Area PVC | Work area cabling | FR-PVC | 5.3 |
7562004xxx | Cat. 5e 4x2x24/1 AWG U/UTP PVC | Indoor use, fixed installations | FR-PVC | 5.0 |
7568204xxx | Cat. 5e 2x(4x2x24/1 AWG) FIG-8 U/UTP PVC P Fig-8 | Indoor use, fixed installations | FR-PVC | 5.1 |
8371204xxx | Cat. 5e 4x2x24/1 AWG F/UTP PVC | Indoor use, fixed installations | FR-PVC | 6.1 |
8391304xxx | Cat. 5e 4x2x24/1 AWG F/UTP Outdoor Low Temperatures PVC | Indoor/Outdoor use, fixed installations | UV resistant FR-PVC | 7.2 |
8371804xxx | Cat. 5e 2x(4x2x24/1 AWG) FIG-8 F/UTP PVC | Trunking | FR-PVC | 6.1 |
8371406xxx | Cat. 5e 6x(4x2x24 AWG F/UTP) Multi-Cable PVC | Indoor use, fixed installations | FR-PVC | 20 |
8371412xxx | Cat. 5e 12x(4x2x24 AWG F/UTP) Multi-Cable PVC | Indoor use, fixed installations | FR-PVC | 27.6 |
8371425xxx | Cat. 5 25x(4x2x24 AWG F/UTP) Multi-Cable PVC | Trunk Cable for Local Area Networks | FR-PVC | 35.5 |
Category 6, 100 Ohm
250 MHz Data Transmission Tables
The GIGA-STAR Solution is a complete line of data-transmission cables horizontal and work area types, designed for Cat. 6 and Cat. 5e for use in CLASS D and CLASS E cabling systems.
GIGA-STAR cables are tested up to 300 MHz, and are fully compatible with ISO/IEC 11801, IEC 61156-5, IEC 61156-6, and TIA/EIA 568C.
The GIGA-STAR Solution is consists of the following three groups:
- U/UTP cables, where high NEXT and FEXT loss values are achieved by mechanical pair separation
- U/FTP cables, where high NEXT and FEXT loss values are achieved by individual pair shielding
- S/FTP cables, where an additional overall braid shield provides outstanding EMC performance
Our customers have the option of selecting a true Category 6 cable that meets all the transmission parameters required to support the advanced applications with 3 different levels of EMC performance:
- U/UTP cables: 50 dB coupling attenuation
- U/FTP cables: 75 dB coupling attenuation
- S/FTP cables: 85 dB coupling attenuation
All GIGA-STAR cables feature high values of PS-ACR and PS-ELFEXT, and a stable 100 Ohm characteristic impedance ensuring very low Return-Loss, making The GIGA-STAR Solution ideal for GIGABIT-Ethernet applications. All cables are available with a PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jacket and in a single or “Siamese twin” (FIG-8) construction.
Category 6 Data Transmission Cables
Part Number | Product Description | Computer & LAN Applications | Outer Jacket Material | Outer Diameter (mm nom.) |
---|---|---|---|---|
720KZ04xxx | Cat. 6 4x2x24/7 AWG U/UTP Work Area PVC | High bandwidth digital applications with low BER | FR-PVC | 6.5 |
9828022xxx | Cat. 6 4x2x26/7 AWG U/FTP Work Area PVC | High bandwidth digital applications with low BER | FR-PVC | 6.3 |
9828026xxx | Cat. 6 4x2x26/7 AWG S/FTP Work Area PVC | High bandwidth digital applications with low BER | FR-PVC | 6.4 |
750AZ04xxx | Cat. 6 4x2x23/1 AWG U/UTP PVC | Indoor use, fixed installations | FR-PVC | 6.7 |
750BZ04xxx | Cat. 6 4x2x23/1 AWG U/UTP FRLSZH | Data-Centers/SANs | FR-LSZH | 6.6 |
750BZR4101 | Cat. 6 4x2x23/1 AWG U/UTP SWA Outdoor Direct Burial LSZH | Trunk Cable for Local Area Networks | UV resistant PO compound | 12.7 |
750UZ04xxx | Cat. 6 4x2x23/1 AWG U/UTP Indoor/Outdoor FR-LSZH/FR-LSZH | Low temperature Indoor/Outdoor applications | FR-LSZH | 8.3 |
8300204xxx | Cat. 6 4x2x23/1 AWG U/FTP FRLSZH | Indoor use, fixed installations | FR-LSZH | 7.3 |
8300804xxx | Cat. 6 2x(4x2x23/1 AWG) FIG-8 U/FTP FR-LSZH | Trunk Cable for Local Area Networks | FR-LSZH | 7.6 |
8300904101 | Cat. 6 4x2x23/1 AWG U/FTP Outdoor LSZH | Indoor/Outdoor use, fixed installations | FR-LSZH | 9.6 |
8300C04101 | Cat. 6 4x2x23/1 AWG U/FTP CSA FR-LSZH/PE | Outdoor and direct burial installations | UV Resistant FR-PO | 13.2 |
830D104xxx | Cat. 6 4x2x23/1 AWG U/FTP Drop PVC | Trunk Cable for Local Area Networks | UV resistant FR-PVC | 7.4 |
Category 6A, 100 Ohm
500 MHz Data Transmission Cables
Giga-Ten Solution cables is a complete line of data-transmission horizontal and work area cables, designed for state-of-the-art cabling systems including Class EA of ISO/IEC 11801 and Cat. 6A of IEC 61156-5/6.
These cables are tested up to 650 MHz, and are fully compatible with the ISO/IEC 11801, IEC 61156-5, IEC 61156-6, and TIA/EIA 568C.
Cat. 6A cables come in the following designs:
- U/FTP cables grounded, where high AXT, NEXT and FEXT attenuation values are achieved by individual pair shielding
- U/FTP cables ungrounded, where high AXT, NEXT and FEXT attenuation values are achieved by individual pair shielding. These cables may be terminated with non-shielded connecting hardware with out any performance or EMC issues
- F/FTP cables, where high AXT, NEXT and FEXT attenuation values are achieved by both overall and individual pair aluminium foil shields
- S/FTP cables, where high AXT, NEXT and FEXT attenuation values are achieved by both overall copper braid and individual pair aluminium foil shields. This structure is recommended for PoE (Power over Ethernet) applications
Giga-Ten Cat. 6A Solution cables have Coupling Attenuation complying with Type II and Type I (depending on shield design) requirements per IEC 61156-5/6 therefore AXT performance is proven by design.
The cable’s high values of PS-ACR and PS-ELFEXT attenuation, and a stable 100 Ohm characteristic impedance ensuring very low Return-Loss, make it ideal for 1 and 10 GIGABIT-Ethernet applications.
All cables are available with a PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jackets as well as other compounds, and in single or “Siamese twin” (FIG-8) constructions.
Category 6A Data Transmission Cables
Part Number | Product Description | Computer & LAN Applications | Outer Jacket Material | Outer Diameter (mm nom.) |
---|---|---|---|---|
9828U22xxx | Cat. 6A 4x2x26/7 AWG U/FTP Ungrounded U/UTP use Workarea FRLSZH | High bandwidth digital applications with low BER | FR-LSZH | 6.1 |
9828U61xxx | Cat. 6A 4x(2x24/1 AWG) U/FTP ungrounded FR-LSZH | Indoor use, fixed installations | FR-LSZH | 6.4 |
9828U71xxx | Cat. 6A 4x(2x24/1 AWG) U/FTP ungrounded FR-PVC | Indoor use, fixed installations | FR-PVC | 6.4 |
9828G22xxx | Cat. 6A 4x2x26/7 AWG U/FTP Work Area FR-LSZH | High bandwidth digital applications with low BER | FR-LSZH | 6.0 |
9828G24xxx | Cat. 6A 4x2x0.45/1 mm U/FTP Work Area FR-LSZH | High bandwidth digital applications with low BER | FR-LSZH | 6.3 |
83U0204xxx | Cat. 6A 4x2x23/1 AWG U/FTP Ungrounded U/UTP use FR-LSZH | Indoor use, fixed installations | FR-LSZH | 7.4 |
83UM204xxx | Cat. 6A 4x2x23/1 AWG U/FTP Ungrounded U/UTP use FR-LSZH IEC 60332-3 | Indoor use, fixed installations | FR-LSZH | 8.0 |
83G0204xxx | Cat. 6A 4x2x23/1 AWG U/FTP FR-LSZH | Indoor use, fixed installations | FR-LSZH | 7.3 |
83G0208xxx | Cat. 6A 2x(4x2x23/1 AWG) FIG-8 U/FTP FR-LSZH | Indoor use, fixed installations | FR-LSZH | 7.3 |
83GU204xxx | Cat. 6A 4x2x23/1 AWG U/FTP Indoor/Outdoor FR-LSZH/HFFR-PU | Indoor/Outdoor use, fixed installations | FR-PVC | 9.0 |
Category 7, 100 Ohm
600 MHz Data Transmission Cables
The GIGA-DOR Solution is a complete line of high-performance Cat. 7 horizontal and work area data cables, designed for CLASS F links and for advanced high data-rate networks, available in a wide range of constructions.
GIGA-DOR Solution cables conform to the ISO/IEC 11801 requirements for Cat. 7 cables as specified in IEC 61156-5 and 61156-6. These cables are composed of balanced twisted pairs having a nominal 100 Ohm characteristic impedance up to 600 MHz, with a very high NEXT loss.
The high NEXT loss, achieved by individual aluminium foil pair shields, provides a typical margin of 60 dB ACR over U/UTP cables, making GIGA-Solution cables ideal for multiple high-frequency services.
GIGA-DOR & GIGA-DOR Jr. S/FTP horizontal cables and GIGA-Patch 4 pair S/FTP 26 AWG work area (patch) cables are overall shielded with a tin-coated copper braid. When properly grounded, this copper braid and the individual aluminium foil shields provide exceptional EMC performance, having a minimum coupling attenuation of 90 dB.
All cables are available with flame-retardant PVC or halogen-free (HFFR) jackets, in a range of colors, in single or “Siamese” twin (FIG-8) constructions.
Category 7 Data Transmission Cables
Part Number | Product Description | Computer & LAN Applications | Outer Jacket Material | Outer Jacket Material (mm nom.) |
---|---|---|---|---|
9928244xxx | Cat. 7 4x2x26/7 AWG S/FTP Work Area FR-LSZH | High data rates | FR-LSZH | 6.4 |
9928264xxx | Cat. 7 4x2x26/7 AWG S/FTP Work Area PU | Outdoor installations | PU | 6.5 |
9928312xxx | Cat. 7 12x(4x2x26/7 AWG S/FTP) Multi-Cable Work Area FR-LSZH | Indoor Backbone | FR-LSZH | 27.8 |
9827A54xxx | Cat. 7 4x2x23/1 AWG F/FTP FRLSZH | Indoor use, fixed installations | FR-LSZH | 7.4 |
9928675xxx | Cat. 7 1000 MHz 4x2x23/1 AWG S/FTP FR-LSZH | Indoor use, fixed installations | FR-LSZH | 7.5 |
9928654xxx | Cat. 7 4x2x23/1 AWG S/FTP FRLSZH | Data-Centers/SANs | FR-LSZH | 8.0 |
9928554xxx | Cat. 7 4x2x22/1 AWG S/FTP FRLSZH | Indoor use, fixed installations | FR-LSZH | 8.2 |
9928692xxx | Cat. 7 2x(4x2x23/1 AWG) FIG-8 S/FTP FR-LSZH | Data-Centers/SANs | FR-LSZH | 8.0 |
9928604xxx | Cat. 7 4x2x23/1 AWG S/FTP FR-PVC | Indoor use, fixed installations | FR-PVC | 7.8 |
9928659xxx | Cat. 7 4x2x23/1 AWG S/FTP CSA Direct Burial PE | Outdoor and direct burial installations | PE | 12.0 |
Category 7A, 100 Ohm
1000 MHZ Data Transmission Cables
Giga-Ten Solution cables are a complete line of horizontal and work area data-transmission cables, designed for state-of-the-art cabling systems including IEEE 802.3ae, ISO/IEC 11801 otherwise known as 10 GBaseT.
These cables are tested up to 1200 MHz, and are fully compatible with the ISO/IEC 11801, IEC 61156-5, and IEC 61156-6 with the highest coupling attenuation level Type I, which makes the application to be defined as “Alien Crosstalk proven by design”.
Giga-Ten Solution cables come in S/FTP shielding structure where very high NEXT and FEXT values and outstanding EMC performance are achieved.
Giga-Ten Solution cables have Coupling Attenuation complying with Type I requirements as per IEC 61156 therefor the AXT requirements are achieved by design, and feature high values of PS-ACR and PS-ELFEXT attenuations together with a stable 100 Ohm characteristic impedance ensuring high Return-Loss attenuation, making them ideal for very high bandwidth applications as 10 GBase-T.
Giga-Ten horizontal and work area cables are compatible with shielded RJ45 connecting hardware, allowing use in variety of communication application including Video Over Ethernet and IEEE 802.3af (Power over Ethernet) and IEEE 802.3at (Power over Ethernet Plus).
The cables are available with a FR-PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jacket and in single or “Siamese twin” (FIG-8) constructions.
Category 7A Data Transmission Cables
Part Number | Product Description | Computer & LAN Applications | Outer Jacket Material | Outer Diameter (mm nom.) |
---|---|---|---|---|
992G244xxx | Cat. 7A 4x2x26/7 AWG S/FTP Work Area FR-LSZH | High bandwidth digital applications with low BER | FR-LSZH | 6.3 |
99XG504xxx | Cat. 7A 4x2x23/1 AWG S/FTP FRLSZH | Data-Centers/SANs | FR-LSZH | 8.1 |
99XG508xxx | Cat. 7A 2x(4x2x23/1 AWG) FIG-8 S/FTP FR-LZSH | Data-Centers/SANs | FR-LSZH | 8.1 |
99XG254xxx | Cat. 7A 4x2x22/1 AWG S/FTP FRLSZH | Indoor use, fixed installations | FR-LSZH | 8.7 |
99XG258xxx | Cat. 7A 2x(4x2x22/1 AWG) FIG-8 S/FTP FR-LSZH | Indoor Backbone | FR-LSZH | 8.7 |
99XG524xxx | Cat. 7A 4x2x23/1 AWG S/FTP ND FR-LSZH IEC60332-3 | Indoor use, fixed installations | FR-LSZH | 8.4 |
99XG954xxx | Cat. 7A 4x2x22/1 AWG S/FTP OUTDOOR PVC | Outdoor installations | UV resistant FR-PVC | 10.4 |
99XGM07xxx | Cat. 7A 7x(4x2x23/1 AWG) S/FTP) Multi-Cable FR-LSZH | Indoor Backbone | FR-LSZH | 27.5 |
99XGM12xxx | Cat. 7A 12x(4x2x23/1 AWG) S/FTP) Multi-Cable FR-LSZH | Indoor Backbone | FR-LSZH | 35 |
99XG544xxx | Cat. 7A 4x2x23/1 AWG S/FTP FRLSZH | Data-Centers/SANs | FR-LSZH | 8.0 |
99XG548xxx | Cat. 7A 2x(4x2x23/1 AWG) FIG-8 S/FTP FR-LZSH | Data-Centers/SANs | FR-LSZH | |
99XG854xxx | Cat. 7A 4x2x23/1 AWG S/FTP FRLSZH/PVC | Data-Centers/SANs | FR-PVC | 10.4 |