Data Cable – Cat 5, Cat 6, Cat 7

New – Cat6 Outdoor Rated & Shielded Cable from Times Microwave

Times Microwave has just released its new CAT6 SFTP LAN Data Cable, 4 pairs 23AWG

Featuring, high coverage tinned copper outer shield for superior grounding, better than 90dB RF Shielding effectiveness, ripcord for easy jacket stripping, 8mm O/D, black PE Jacket for excellent weather resistance.

TMS – Cat-6 Outdoor Rate & Shielded

CAT7 E10 MHz 4-Pair solid S/FTP, Low Smoke, Zero Halogen Cable Violet Jacket

This is a fully shield cable with individual foils around each pair, coupled with high screen
coverage outer braid for a high level of immunity to outside interference’s.
In PoE remote power applications, this cable can be installed in environments up to 60
degrees Celsius without degradation suffered by heat rise inside the cable bundle. This 7A cable
can also be used for cable sharing from one drop ideal for running multiple lower speed
applications.

CAT7A-4PLSZH Cable

Data Cable – Cat 5, Cat 6, Cat 7

The fundamental importance of the Data Centres and the need to provide for daily increasing applications, transmission speeds and data storage, businesses are investing in the amount of equipment their Data Centres must support. Consequently, IT managers must design scalable Data Centres to support their future growth and potentially new technologies, while ensuring the best performance.

Rojone supplies high quality Data cables consist of Cat.5e to Cat.7A multi-cable, multi-pair and multi-core structures solid and matched work area cables.

All cables are fully compatible with the standard connecting hardware (i.e. RJ-45).

All products are available with FR-LSZH, PVC, PU and PE jackets combined with different optional shielding structures such as S/FTP, SF/UTP, F/UTP, U/FTP.

The cables are designed with optimised lay lengths, size, transmission performance and structures to enable peak high density data-centre cabling.

High-density cabling creates less congestion in pathways which means better cooling conditions in particular for PoE and PoE+ applications, lower installation time, minimises down time, accelerates recovery time, minimises site access by non-essential personnel, and allows place-and plug modular installation for Gigabit and up to 10 Gigabit applications.

Category 5e, 100 Ohm

100 MHz Data Transmission Cables

The basic solution is a complete line of high-performance 100 Ohm cables, conforming to Category 5e in accordance with TIA/EIA-568-C, ISO/IEC 11801, IEC 61156-5, IEC 61156-6 and CENELEC prEN 50288, supporting CLASS D (new) Links.

The product range includes Horizontal, Working area (Patch) and Backbone Cables, available in a wide range of constructions, including U/UTP, F/UTP, SF/UTP and S/FTP.

All cables are available with PVC, PU (Polyurethane), PE (Polyethylene) and FR-LSZH (Flame Retardant Low Smoke Zero Halogen) jackets, in single or “Siamese twin” (FIG-8), multi-cable, or multi-core constructions.

Category 5e Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Diameter (mm nom.)
4T00080101Cat. 5e 4x2x24/1 AWG U/F/UTP + 17 AWG CCS Fig-8 Double Jacket Outdoor UL1581-VW1/CMX Jacket Outdoor UL1581-VW1/CMXOutdoor installationsUV resistant FR-PVC7.9
8393204xxxCat. 5e 4x2x24/1 AWG F/UTP Outdoor PVC/PVC UL (1581 VW 1) (UL) LISTED E211498Outdoor installationsUV resistant FR-PVC7.9
7272604xxxCat. 5e 4x2x26/7 AWG Work Area U/UTP PVCIndoor use, fixed or portable installationsFR-PVC4.9
8272626xxxCat. 5e 4x2x26/7 AWG F/UTP Work Area PVCWork area cablingFR-PVC5.70
9292604xxxCat. 5 4x2x26/7 AWG SF/UTP Work Area PVCWork area cablingFR-PVC5.3
7562004xxxCat. 5e 4x2x24/1 AWG U/UTP PVCIndoor use, fixed installationsFR-PVC5.0
7568204xxxCat. 5e 2x(4x2x24/1 AWG) FIG-8 U/UTP PVC P Fig-8Indoor use, fixed installationsFR-PVC5.1
8371204xxxCat. 5e 4x2x24/1 AWG F/UTP PVCIndoor use, fixed installationsFR-PVC6.1
8391304xxxCat. 5e 4x2x24/1 AWG F/UTP Outdoor Low Temperatures PVCIndoor/Outdoor use, fixed installationsUV resistant
FR-PVC
7.2
8371804xxxCat. 5e 2x(4x2x24/1 AWG) FIG-8 F/UTP PVC TrunkingFR-PVC6.1
8371406xxxCat. 5e 6x(4x2x24 AWG F/UTP) Multi-Cable PVCIndoor use, fixed installationsFR-PVC20
8371412xxxCat. 5e 12x(4x2x24 AWG F/UTP) Multi-Cable PVCIndoor use, fixed installationsFR-PVC27.6
8371425xxxCat. 5 25x(4x2x24 AWG F/UTP) Multi-Cable PVCTrunk Cable for Local Area NetworksFR-PVC35.5

Category 6, 100 Ohm

250 MHz Data Transmission Tables

The GIGA-STAR Solution is a complete line of data-transmission cables horizontal and work area types, designed for Cat. 6 and Cat. 5e for use in CLASS D and CLASS E cabling systems.

GIGA-STAR cables are tested up to 300 MHz, and are fully compatible with ISO/IEC 11801, IEC 61156-5, IEC 61156-6, and TIA/EIA 568C.

The GIGA-STAR Solution is consists of the following three groups:

  • U/UTP cables, where high NEXT and FEXT loss values are achieved by mechanical pair separation
  • U/FTP cables, where high NEXT and FEXT loss values are achieved by individual pair shielding
  • S/FTP cables, where an additional overall braid shield provides outstanding EMC performance

Our customers have the option of selecting a true Category 6 cable that meets all the transmission parameters required to support the advanced applications with 3 different levels of EMC performance:

  • U/UTP cables: 50 dB coupling attenuation
  • U/FTP cables: 75 dB coupling attenuation
  • S/FTP cables: 85 dB coupling attenuation

All GIGA-STAR cables feature high values of PS-ACR and PS-ELFEXT, and a stable 100 Ohm characteristic impedance ensuring very low Return-Loss, making The GIGA-STAR Solution ideal for GIGABIT-Ethernet applications. All cables are available with a PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jacket and in a single or “Siamese twin” (FIG-8) construction.

Category 6 Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Diameter (mm nom.)
720KZ04xxxCat. 6 4x2x24/7 AWG U/UTP Work Area PVCHigh bandwidth digital applications with low BERFR-PVC6.5
9828022xxxCat. 6 4x2x26/7 AWG U/FTP Work Area PVCHigh bandwidth digital applications with low BERFR-PVC6.3
9828026xxxCat. 6 4x2x26/7 AWG S/FTP Work Area PVCHigh bandwidth digital applications with low BERFR-PVC6.4
750AZ04xxxCat. 6 4x2x23/1 AWG U/UTP PVCIndoor use, fixed installationsFR-PVC6.7
750BZ04xxxCat. 6 4x2x23/1 AWG U/UTP FRLSZHData-Centers/SANsFR-LSZH6.6
750BZR4101Cat. 6 4x2x23/1 AWG U/UTP SWA Outdoor Direct Burial LSZHTrunk Cable for Local Area NetworksUV resistant PO compound12.7
750UZ04xxxCat. 6 4x2x23/1 AWG U/UTP Indoor/Outdoor FR-LSZH/FR-LSZHLow temperature Indoor/Outdoor applicationsFR-LSZH8.3
8300204xxxCat. 6 4x2x23/1 AWG U/FTP FRLSZHIndoor use, fixed installationsFR-LSZH7.3
8300804xxxCat. 6 2x(4x2x23/1 AWG) FIG-8 U/FTP FR-LSZHTrunk Cable for Local Area NetworksFR-LSZH7.6
8300904101Cat. 6 4x2x23/1 AWG U/FTP Outdoor LSZHIndoor/Outdoor use, fixed installationsFR-LSZH9.6
8300C04101Cat. 6 4x2x23/1 AWG U/FTP CSA FR-LSZH/PEOutdoor and direct burial installationsUV Resistant FR-PO13.2
830D104xxxCat. 6 4x2x23/1 AWG U/FTP Drop PVCTrunk Cable for Local Area NetworksUV resistant FR-PVC7.4

Category 6A, 100 Ohm

500 MHz Data Transmission Cables

Giga-Ten Solution cables is a complete line of data-transmission horizontal and work area cables, designed for state-of-the-art cabling systems including Class EA of ISO/IEC 11801 and Cat. 6A of IEC 61156-5/6.

These cables are tested up to 650 MHz, and are fully compatible with the ISO/IEC 11801, IEC 61156-5, IEC 61156-6, and TIA/EIA 568C.

Cat. 6A cables come in the following designs:

  • U/FTP cables grounded, where high AXT, NEXT and FEXT attenuation values are achieved by individual pair shielding
  • U/FTP cables ungrounded, where high AXT, NEXT and FEXT attenuation values are achieved by individual pair shielding. These cables may be terminated with non-shielded connecting hardware with out any performance or EMC issues
  • F/FTP cables, where high AXT, NEXT and FEXT attenuation values are achieved by both overall and individual pair aluminium foil shields
  • S/FTP cables, where high AXT, NEXT and FEXT attenuation values are achieved by both overall copper braid and individual pair aluminium foil shields. This structure is recommended for PoE (Power over Ethernet) applications

Giga-Ten Cat. 6A Solution cables have Coupling Attenuation complying with Type II and Type I (depending on shield design) requirements per IEC 61156-5/6 therefore AXT performance is proven by design.

The cable’s high values of PS-ACR and PS-ELFEXT attenuation, and a stable 100 Ohm characteristic impedance ensuring very low Return-Loss, make it ideal for 1 and 10 GIGABIT-Ethernet applications.

All cables are available with a PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jackets as well as other compounds, and in single or “Siamese twin” (FIG-8) constructions.

Category 6A Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Diameter (mm nom.)
9828U22xxxCat. 6A 4x2x26/7 AWG U/FTP Ungrounded U/UTP use Workarea FRLSZHHigh bandwidth digital applications with low BERFR-LSZH6.1
9828U61xxxCat. 6A 4x(2x24/1 AWG) U/FTP ungrounded FR-LSZHIndoor use, fixed installationsFR-LSZH6.4
9828U71xxxCat. 6A 4x(2x24/1 AWG) U/FTP ungrounded FR-PVCIndoor use, fixed installationsFR-PVC6.4
9828G22xxxCat. 6A 4x2x26/7 AWG U/FTP Work Area FR-LSZHHigh bandwidth digital applications with low BERFR-LSZH6.0
9828G24xxxCat. 6A 4x2x0.45/1 mm U/FTP Work Area FR-LSZHHigh bandwidth digital applications with low BERFR-LSZH6.3
83U0204xxxCat. 6A 4x2x23/1 AWG U/FTP Ungrounded U/UTP use FR-LSZHIndoor use, fixed installationsFR-LSZH7.4
83UM204xxxCat. 6A 4x2x23/1 AWG U/FTP Ungrounded U/UTP use FR-LSZH IEC 60332-3Indoor use, fixed installationsFR-LSZH8.0
83G0204xxxCat. 6A 4x2x23/1 AWG U/FTP FR-LSZHIndoor use, fixed installationsFR-LSZH7.3
83G0208xxxCat. 6A 2x(4x2x23/1 AWG) FIG-8 U/FTP FR-LSZHIndoor use, fixed installationsFR-LSZH7.3
83GU204xxxCat. 6A 4x2x23/1 AWG U/FTP Indoor/Outdoor FR-LSZH/HFFR-PUIndoor/Outdoor use, fixed installationsFR-PVC9.0

Category 7, 100 Ohm

600 MHz Data Transmission Cables

The GIGA-DOR Solution is a complete line of high-performance Cat. 7 horizontal and work area data cables, designed for CLASS F links and for advanced high data-rate networks, available in a wide range of constructions.

GIGA-DOR Solution cables conform to the ISO/IEC 11801 requirements for Cat. 7 cables as specified in IEC 61156-5 and 61156-6. These cables are composed of balanced twisted pairs having a nominal 100 Ohm characteristic impedance up to 600 MHz, with a very high NEXT loss.

The high NEXT loss, achieved by individual aluminium foil pair shields, provides a typical margin of 60 dB ACR over U/UTP cables, making GIGA-Solution cables ideal for multiple high-frequency services.

GIGA-DOR & GIGA-DOR Jr. S/FTP horizontal cables and GIGA-Patch 4 pair S/FTP 26 AWG work area (patch) cables are overall shielded with a tin-coated copper braid. When properly grounded, this copper braid and the individual aluminium foil shields provide exceptional EMC performance, having a minimum coupling attenuation of 90 dB.

All cables are available with flame-retardant PVC or halogen-free (HFFR) jackets, in a range of colors, in single or “Siamese” twin (FIG-8) constructions.

Category 7 Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Jacket Material (mm nom.)
9928244xxxCat. 7 4x2x26/7 AWG S/FTP Work Area FR-LSZHHigh data ratesFR-LSZH6.4
9928264xxxCat. 7 4x2x26/7 AWG S/FTP Work Area PUOutdoor installationsPU6.5
9928312xxxCat. 7 12x(4x2x26/7 AWG S/FTP) Multi-Cable Work Area FR-LSZHIndoor BackboneFR-LSZH27.8
9827A54xxxCat. 7 4x2x23/1 AWG F/FTP FRLSZHIndoor use, fixed installationsFR-LSZH7.4
9928675xxxCat. 7 1000 MHz 4x2x23/1 AWG S/FTP FR-LSZHIndoor use, fixed installationsFR-LSZH7.5
9928654xxxCat. 7 4x2x23/1 AWG S/FTP FRLSZHData-Centers/SANsFR-LSZH8.0
9928554xxxCat. 7 4x2x22/1 AWG S/FTP FRLSZHIndoor use, fixed installationsFR-LSZH8.2
9928692xxxCat. 7 2x(4x2x23/1 AWG) FIG-8 S/FTP FR-LSZHData-Centers/SANsFR-LSZH8.0
9928604xxxCat. 7 4x2x23/1 AWG S/FTP FR-PVCIndoor use, fixed installationsFR-PVC7.8
9928659xxxCat. 7 4x2x23/1 AWG S/FTP CSA Direct Burial PEOutdoor and direct burial installationsPE12.0

Category 7A, 100 Ohm

1000 MHZ Data Transmission Cables

Giga-Ten Solution cables are a complete line of horizontal and work area data-transmission cables, designed for state-of-the-art cabling systems including IEEE 802.3ae, ISO/IEC 11801 otherwise known as 10 GBaseT.

These cables are tested up to 1200 MHz, and are fully compatible with the ISO/IEC 11801, IEC 61156-5, and IEC 61156-6 with the highest coupling attenuation level Type I, which makes the application to be defined as “Alien Crosstalk proven by design”.

Giga-Ten Solution cables come in S/FTP shielding structure where very high NEXT and FEXT values and outstanding EMC performance are achieved.

Giga-Ten Solution cables have Coupling Attenuation complying with Type I requirements as per IEC 61156 therefor the AXT requirements are achieved by design, and feature high values of PS-ACR and PS-ELFEXT attenuations together with a stable 100 Ohm characteristic impedance ensuring high Return-Loss attenuation, making them ideal for very high bandwidth applications as 10 GBase-T.

Giga-Ten horizontal and work area cables are compatible with shielded RJ45 connecting hardware, allowing use in variety of communication application including Video Over Ethernet and IEEE 802.3af (Power over Ethernet) and IEEE 802.3at (Power over Ethernet Plus).

The cables are available with a FR-PVC or Flame Retardant Low-Smoke Zero-Halogen (FR-LSZH \ HFFR) jacket and in single or “Siamese twin” (FIG-8) constructions.

Category 7A Data Transmission Cables

Part NumberProduct DescriptionComputer & LAN ApplicationsOuter Jacket MaterialOuter Diameter (mm nom.)
992G244xxxCat. 7A 4x2x26/7 AWG S/FTP Work Area FR-LSZHHigh bandwidth digital applications with low BERFR-LSZH6.3
99XG504xxxCat. 7A 4x2x23/1 AWG S/FTP FRLSZHData-Centers/SANsFR-LSZH8.1
99XG508xxxCat. 7A 2x(4x2x23/1 AWG) FIG-8 S/FTP FR-LZSHData-Centers/SANsFR-LSZH8.1
99XG254xxxCat. 7A 4x2x22/1 AWG S/FTP FRLSZHIndoor use, fixed installationsFR-LSZH8.7
99XG258xxxCat. 7A 2x(4x2x22/1 AWG) FIG-8 S/FTP FR-LSZHIndoor BackboneFR-LSZH8.7
99XG524xxxCat. 7A 4x2x23/1 AWG S/FTP ND FR-LSZH IEC60332-3Indoor use, fixed installationsFR-LSZH8.4
99XG954xxxCat. 7A 4x2x22/1 AWG S/FTP OUTDOOR PVCOutdoor installationsUV resistant FR-PVC10.4
99XGM07xxxCat. 7A 7x(4x2x23/1 AWG) S/FTP) Multi-Cable FR-LSZHIndoor BackboneFR-LSZH27.5
99XGM12xxxCat. 7A 12x(4x2x23/1 AWG) S/FTP) Multi-Cable FR-LSZHIndoor BackboneFR-LSZH35
99XG544xxxCat. 7A 4x2x23/1 AWG S/FTP FRLSZHData-Centers/SANsFR-LSZH8.0
99XG548xxxCat. 7A 2x(4x2x23/1 AWG) FIG-8 S/FTP FR-LZSHData-Centers/SANsFR-LSZH
99XG854xxxCat. 7A 4x2x23/1 AWG S/FTP FRLSZH/PVCData-Centers/SANsFR-PVC10.4